STAMP SOLENOID AND ORIGINAL EXIT SENSOR
SM 10-29 B386
4.11 STAMP SOLENOID AND ORIGINAL EXIT SENSOR
1. Remove the rear cover (1 connector). Also remove the upper cover (the exit
tray).
2. Open the exit guide plate [A]. Next, detach the unit by inserting a screwdriver or
other tool into one of the small openings [B] on either side of the guide plate
holder and pushing firmly.
3. Remove the stamp solenoid [C] (1 screw).
4. Remove the original exit sensor [D] (1 connector).
B386R509.WMF
B386R203.WMF
[A]
[B]
[C]
[D]