SERVICE PROGRAM MODE
SM 3-3 B576
Fax Option
B576
SP2-XXX (RAM Data)
2
Mode No. Function
RAM Read/Write 101
001
Change RAM data for the fax board directly.
! Section 3.5 Service RAM Addresses
Memory Dump
001 G3-1 Memory Dump
Print out RAM data for the fax board. !
Section 3.5 Service RAM Addresses
002 G3-2 Memory Dump Print out RAM data for the SG3 board.
102
004 Not used. Do not change setting.
G3-1 NCU Parameters 103
001 – 023 CC, 01 – 22
NCU parameter settings for the standard
G3 board. ! Section 3.3 NCU Parameters
G3-2 NCU Parameters 104
001 – 023 CC, 01 – 22
NCU parameter settings for the optional G3
board. ! Section 3.3 NCU Parameters
SP3-XXX (Machine Settings)
3
Mode No. Function
Service Station
001 Fax Number Enter the fax number of the service station.
101
002 Select Line Select the line type.
Serial Number 102
000 Enter the fax unit’s serial number.
PSTN-1 Port Settings
001 Select Line
Select the line type setting for the G3-1 line.
If the machine is installed on a PABX line,
select “PABX”, “PABX(GND)” or
“PABX(FLASH)”.
002 PSTN Access Number
Enter the PSTN access number for the
G3-1 line.
103
003
Memory Lock
Disabled
If the customer does not want to receive
transmissions using Memory Lock on this
line, turn this SP on.
104 PSTN-2 Port Settings
001 Select Line
Select the line setting for the G3-2 line. If
the machine is installed on a PABX line,
select “PABX”, “PABX(GND)” or
“PABX(FLASH)”.
002 PSTN Access Number
Enter the PSTN access number for the G3-
2 line.