SERVICE PROGRAM MODE
B089/B093 4-34 SM
SP5XXX: Mode
mm/inch Selection 5024*
Selects whether mm or inches are used in the display.
Note: After selecting the number, you must turn the main power switch off and on.
Europe/Asia model: [0 = mm / 1 = inch]
American model: [0 = mm / 1 = inch]
5044 Operation Panel Bit SW
5044 1 SW1 DFU
5044 2 SW2 DFU
A3/DLT Double Count 5104*
Specifies whether the counter is doubled for A3/11" x 17" paper.
If “Yes” is selected, the total counter (mechanical counter) and the current user
code counter counts up twice when A3/11" x 17" paper is used.
[0 = No / 1 = Yes]
ADS Level Selection 5106*
Selects the image density level that is used in ADS mode.
[1 ~ 7 / 4 / 1 notch/step]
Option Counter Type 5113*
Selects the optional counter type.
0 = No
1 = Key Card1
2 = Key Card2
3 = Pre-paid Card
4 = Coin lock
5 = MF key card
11: MF key card (Increment)
12: MF key card (Decrement)
5118* Disable Copying
DFU
Mode Clear Opt. Counter Removal 5120*
This SP is for Japan only. Do not change the value.
[0 = Yes / 1 = Stand-by / 2 = None]
Counter Up Timing 5121*
Determines whether the total counter counts up at paper feed-in or at paper exit.
[0 = Feed In / 1 = Exit]
APS Off Mode 5127*
Selects whether APS mode is selected as the power-up default.
[0 = Enable / 1 = Disabled]