SERVICE PROGRAM MODE
B089/B093 4-64 SM
7508* Original Jam History
7508 1 Last
7508 2 Last 1
7508 3 Last 2
7508 4 Last 3
7508 5 Last 4
7508 6 Last 5
7508 7 Last 6
7508 8 Last 7
7508 9 Last 8
7508 10 Last 9
Displays the original jam history (the most recent 10 jams.
Sample Display:
CODE: 007
SIZE: 05h
TOTAL: 0000334
DATE: Mon Mar 15 11:44:50 2000
where:
CODE is the SP7505*** number (see above.
SIZE is the ASAP paper size code in hex.
TOTAL is the total error count (SP7002001)
DATE is the date the jams occurred.
ROM No./Firmware Version 7801
Displays the ROM number and firmware version numbers.
PM Counter Display 7803*
Displays the PM counter since the last PM.
PM Counter Resets 7804
Resets the PM counter. To reset, press Execute on the touch panel.
SC/Jam Counter Reset 7807
Resets the SC and jam counters. To reset, press Execute on the touch panel.
This SP does not reset the jam history counters: SP7507, SP7508.
Resets Counters 7808
Resets all counters except SP7002***, SP7006*** and SP7007***. To reset,
press Execute on the touch panel.
Access Code Clear 7810
Use to clear the key operator code if the key operator forgets the code. After
clearing the code is reset for Null and the password entry display does not open.
To clear, press Execute on the touch panel.
Original Counter Clear 7811
Clears the original total display, displayed with SP7002***. To clear, press
Execute on the touch panel.
7816 Print Counter Reset by Tray
7816 1 By-pass
7816 2 Tray 1
7816 3 Tray 2
7816 4 Tray 3
7816 5 Tray 4
7816 6 LCT
Resets the total copy count by paper tray. To reset, press Execute
on the touch panel. Use these SP modes when replacing the pick-