SERVICE CALL CONDITIONS
B089/B093 7-4 SM
Code No. Symptom Possible Cause
LD drive current over 323 B
The LD drive board applies more than
100 mA to the LD.
LD unit defective (not enough power,
due to aging)
Poor connection between the LD unit
and the SBCU board
SBCU board defective
ID sensor calibration - Error 1 350 B
One of the following conditions
occurred when the ID sensor pattern
was calibrated during printing:
Vsp > 2.5V
Vsg < 2.5V
Vsp = 0V
Vsg = 0V
ID sensor defective or dirty
ID sensor harness disconnected or
connector is damaged
SBCU defective
Scanning system or image creation
system malfunction
High voltage power supply board
(power pack) defective
ID sensor calibration – Error 2 351 B
The following conditions occurred
simultaneously when the ID sensor
pattern was calibrated during printing:
Vsg = 5V
PWM = 0 (LED current drop)
ID sensor dirty or defective
ID sensor harness disconnected, or
connector damaged
SBCU board defective
High voltage power supply board
(power pack) defective
ID sensor calibration – Error 3 352 B
During printing the 2.5V value for edge
detection of the ID sensor pattern could
not be detected after 800 ms.
ID sensor dirty or defective
ID sensor harness disconnected, or
connector damaged
SBCU defective
High voltage power supply board
(power pack) defective
ID sensor adjustment Error 1 353 B
Error occurred during automatic
adjustment of Vsg:
Vsg output did not attain 4V, even
with PWM = 255 (maximum current
for LED)
Vsg output was greater than 4V,
even with PWM=0 (no current for the
LED)
ID sensor dirty or defective
ID sensor harness disconnected, or
connector damaged
SBCU defective
High voltage power supply board
(power pack) defective
Scanning system or image creation
system malfunction
ID Sensor Adjustment Error 2 354 B
Error occurred during automatic
adjustment of Vsg. Vsg could not be
adjusted to 4.0V±0.2V within 50 ms
even after 20 attempts.
ID sensor dirty or defective
ID sensor harness disconnected, or
connector damaged
SBCU defective
High voltage power supply board
(power pack) defective
Scanning system or image creation
system malfunction
ID sensor error 355 C
For details about the cause of the
problem, please refer to SC350~354
above.
ID sensor dirty or defective
ID sensor harness disconnected, or
connector damaged
SBCU board defective
High voltage power supply board
(power pack) defective
Scanning system or image creation
system malfunction

Table of Contents