SERVICE CALL CONDITIONS
B089/B093 7-6 SM
Code No. Symptom Possible Cause
Paper tray motor lock (optional paper
tray unit)
506 B
A motor lock signal is not detected for
more than 1.5 s or the lock signal is not
detected for more than 1.0 s during
rotation.
Paper tray unit motor defective
Too much load on the drive
mechanism
Rear fence drive error (optional LCT) 508 B
The return position sensor is not
activated after the rear fence drive
motor has been on to lower the tandem
tray for 8 seconds.
Rear fence motor defective
Return position sensor defective
Too much load on the drive
mechanism
Side fence drive error (optional LCT) 509 B
The side fence positioning sensor is not
activated for more 3 seconds when the
paper stack in the left tray is moved to
the right tray.
The side fence close sensor is not
activated for more 3 seconds after
moving the paper stack to the right tray.
Side fence motor defective
Side fence position sensor defective
Side fence close sensor defective
Too much load on the drive
mechanism
LCT lower limit error 510 B
The lower limit sensor does not activate
within 8 seconds after the tray has been
lowered.
Tray lift motor defective
Poor connection of the tray lift motor
Lower limit sensor defective
Too much load on the drive
mechanism
Paper tray error 520 B
An error occurs (i.e motor error, or
sensor error, etc) for any paper tray.
A defective motor
A defective sensor
Too much load on the drive
mechanism
Fusing thermistor open 541 A
The fusing temperature detected by the
thermistor was below 0 °C for 5
seconds.
The fusing temperature does not rise
+15 °C (center) or +12 °C (at the ends)
five times within 2 minutes after the
fusing lamps have been turned on.
Fusing thermistor defective or out of
position
Fusing lamp open
Fusing thermostat open
Power supply board defective
Poor connection of the fusing unit
Fusing temperature warm-up error 542 A
The fusing temperature does not reach
the standby temperature within 20
seconds after the main switch is turned
on.
Fusing thermistor defective or out of
position
Fusing lamp open
Fusing thermostat open
Power supply board defective
Poor connection of the fusing unit
Fusing overheat error 1 543 A
A fusing temperature of over 231°C is
detected for 5 second by the fusing
thermistor.
Fusing thermistor defective
Power supply board defective
SBCU board defective
Fusing overheat error 2 544 A
A fusing temperature of over 251°C is
detected by the fusing temperature
monitor circuit in the SBCU board.
Fusing thermistor defective
Power supply board defective
SBCU board defective