BIT SWITCHES
SM 3-33 B576
Fax Option
B576
Communication Switch 16 SP No. 1-104-023
No FUNCTION COMMENTS
0 Not used. Do not change setting.
1
Optional G3 unit (G3-2)
0: Not installed
1: Installed
Change this bit to 1 when installing the first optional
G3 unit.
2 to 7 Not used. Do not change setting.
Communication Switch 17 SP No. 1-104-024
No FUNCTION COMMENTS
0 SEP reception
0: Disabled
1: Enabled
0: Polling transmission to another maker’s machine
using the SEP (Selective Polling) signal is disabled.
1 SUB reception
0: Disabled
1: Enabled
0: Confidential reception to another maker’s
machine using the SUB (Sub-address) signal is
disabled.
2 PWD reception
0: Disabled
1: Enabled
0: Disables features that require PWD (Password)
signal reception.
3-6 Not used Do not change the settings.
7
Action when there is no box
with an F-code that matches
the received SUB code
0: Disconnect the line
1: Receive the message
(using normal reception mode)
Change this setting when the customer requires.
Communication Switch 18 - Not used (do not change the settings)
Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B SP No. 1-104-028
No FUNCTION COMMENTS
0
to
7
Extension access code (0 to 7)
to turn V.8 protocol On/Off
0: On
1: Off
If the PABX does not support V.8/V.34 protocol
procedure, set this bit to “1” to disable V.8.
Example: If “0” is the PSTN access code, set bit 0
to 1. When the machine detects “0” as the first
dialed number, it automatically disables V.8
protocol. (Alternatively, if “3” is the PSTN access
code, set bit 3 to 1.)