BIT SWITCHES
SM 3-49 B576
Fax Option
B576
G3-2 Switch 0A SP No. 1-106-011
No FUNCTION COMMENTS
0
1
Maximum allowable carrier
drop during image data
reception
Bit 1 Bit 0 Value (ms)
0 0 200
0 1 400
1 0 800
1 1 Not used
These bits set the acceptable modem carrier drop
time.
Try using a longer setting if error code 0-22 is
frequent.
2 Non-ECM Carrier Drop
0: Maintain connection
1: Disconnect
Determines how the machine will respond when it
detects a drop in the carrier signal during non-ECM
communication.
3 Not used Do not change the settings.
4
Maximum allowable frame
interval during image data
reception.
0: 5 s 1: 13 s
This bit set the maximum interval between EOL
(end-of-line) signals and the maximum interval
between ECM frames from the other end.
Try using a longer setting if error code 0-21 is
frequent.
5 Not used Do not change the setting.
6
Reconstruction time for the first
line in receive mode
0: 6 s 1: 12 s
When the sending terminal is controlled by a
computer, there may be a delay in receiving page
data after the local machine accepts set-up data and
sends CFR. This is outside the T.30
recommendation. But, if this delay occurs, set this
bit to 1 to give the sending machine more time to
send data.
Refer to error code 0-20.
ITU-T T.30 recommendation: The first line should
come within 5 s of CFR.
7 Not used Do not change the setting.
G3-2 Switch 0B SP No. 1-106-012
No FUNCTION COMMENTS
0
Protocol requirements: Europe
0: Disabled 1: Enabled
1
Protocol requirements: Spain
0: Disabled 1: Enabled
2
Protocol requirements:
Germany
0: Disabled 1: Enabled
3
Protocol requirements: France
0: Disabled 1: Enabled
4
PTT requirements: Germany
0: Disabled 1: Enabled
5
PTT requirements: France
0: Disabled 1: Enabled
The machine does not automatically reset these bits
for each country after a country code (System
Switch 0F) is programmed.
Change the required bits manually at installation.
6-7 Not used Do not change the setting.