PRINTER ENGINE SERVICE MODE 17 January, 2003
5-16
1
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
31 H: Offset Temp *BCU Sets the heating roller temperature for the printing
start condition when changing the process speed.
Fusing temperature must be decreased when the
machine changes to a process speed that is
slower than the current process speed (for
example, when the speed changes from 185 mm/s
to 62.5 mm/s). The machine idles while reducing
the fusing temperature. When the fusing
temperature becomes lower than the ready
temperature, the machine starts printing.
Ready Temperature = Target temperature +
Temperature specified in this SP mode.
[ 1 to 20 / 5
/ 1°C/step]
32 P: Offset Temp *BCU Sets the pressure roller temperature for the
printing start condition when changing the process
speed.
[ 1 to 20 / 10
/ 1°C/step]
33 H:SP 62.5 *BCU
[ -20 to +30 / +10
/ 1°C/step]
34 H:SP 125 *BCU
[ -20 to +30 / +10
/ 1°C/step]
35 H:SP 185 *BCU
[ -20 to +30 / +10
/ 1°C/step]
36 P:SP 62.5 *BCU
[ -20 to +30 / +10
/ 1°C/step]
37 P:SP 125 *BCU
[ -20 to +30 / +10
/ 1°C/step]
105
38 P:SP 185 *BCU
[ -20 to +30 / +20
/ 1°C/step]
[Temp. Display] Fusing Temperature Display (Heating or Pressure)
1 H Roller
106
2 P Roller
Displays the current temperature of the heating
and pressure rollers.
[ 0 to 200 / - / 5°C/step]
[Paper Size] Tray Paper Size
1 Tray 1 A4/LT *BCU Specifies the paper size for tray 1.
[ 0 or 1 / 0
/ - ] Alphanumeric
0: A4 sideways, 1: LT sideways
Tray 1 can only use these two sizes.
US: 1 FA
2 Tray 2 B4/LG *BCU Specifies the paper size for tray 2.
[ 0 or 1 / 0
/ - ] Alphanumeric
0: B4 lengthwise, 1: LG lengthwise
This specifies which size is detected for a sensor
output of 1101 (see section 6 for details).
US: 1 FA
3 Tray 2 A4/LT *BCU Specifies the paper size for tray 2.
[ 0 or 1 / 0
/ - ] Alphanumeric
0: A4 lengthwise, 1: LT lengthwise
This specifies which size is detected for a sensor
output of 0110 (see section 6 for details).
US: 1 FA
902
4 Tray 2 B5/LT
*BCU Specifies the paper size for tray 2.
[ 0 or 1 / 0
/ - ] Alphanumeric
0: LT, 1: B5 lengthwise
This specifies which size is detected for a sensor
output of 1011 (see section 6 for details).