17 January, 2003 OPTIONAL UNIT INSTALLATION
1-39
Installation
1.6.9 ANTI-CONDENSATION HEATER
1. Remove the rear scale [A] (! x 3).
2. Remove the exposure glass [B] with
the left scale [C] (! x 2).
NOTE: You do not have to remove the
ADF exposure glass. If the glass is
removed, position the glass marker
[D] at the rear-left corner when
reattaching.
3. Remove the rear cover [E] (! x 3).
4. Remove the right cover [F] (! x 3).
5. Remove the left cover [G] (! x 3).
6. Remove the rear frame [H] (! x 12, "
x 2).
7. Install the anti-condensation heater [I]
in the rear-left corner of the scanner
unit (! x 2).
8. Pass the cable through the opening [J]
in the rear rail and connect it to the
connector [K] at the front-left corner of
the power supply unit.
9. Reassemble the scanner unit.
G367I106.WMF
G367I107.WMF
G367I219.WMF
[A]
[B]
[C]
[D]
[E]
[F]
[G]
[H]
[I]
[J]
[K]