PRINTER ENGINE SERVICE MODE 17 January, 2003
5-28
2
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
30 [FC,C]B S 62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
31 [FC,C]B S 125 *BCU
[ 0 to 50 / 10
/ 1 µA/step ]
32 [K]OHP 62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
33 [FC,K]OHP 62.5 *BCU
[ 0 to 50 / 8
/ 1 µA/step ]
34 [FC,Y]OHP 62.5 *BCU
[ 0 to 50 / 8
/ 1 µA/step ]
35 [FC,M]OHP 62.5 *BCU
[ 0 to 50 / 4
/ 1 µA/step ]
36 [FC,C]OHP 62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
37 [K]TH R62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
38 [FC,K]TH R62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
39 [FC,Y]TH R62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
40 [FC,M]TH R62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
41 [FC,C]TH R62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
42 [K]SP S62.5 *BCU
[ 0 to 50 / 8
/ 1 µA/step ]
43 [K]SP S125 *BCU
[ 0 to 50 / 15
/ 1 µA/step ]
44 [K]SP S185 *BCU
[ 0 to 50 / 22
/ 1 µA/step ]
45 [FC,K]SP S62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
46 [FC,Y]SP S62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
47 [FC,M]SP 62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
48 [FC,C]SP 62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
49 [FC,K]SP 125 *BCU
[ 0 to 50 / 13
/ 1 µA/step ]
50 [FC,Y]SP 125 *BCU
[ 0 to 50 / 10
/ 1 µA/step ]
51 [FC,M]SP 125 *BCU
[ 0 to 50 / 10
/ 1 µA/step ]
52 [FC,C]SP 125 *BCU
[ 0 to 50 / 10
/ 1 µA/step ]
57 [K]TH S62.5 *BCU
[ 0 to 50 / 6
/ 1 µA/step ]
58 [FC,K]TH S62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
59 [FC,Y]TH S62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
60 [FC,M]TH S62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
61 [FC,C]TH S62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
62 [K]SP D62.5 *BCU
[ 0 to 50 / 10
/ 1 µA/step ]
63 [K]SP D125 *BCU
[ 0 to 50 / 16
/ 1 µA/step ]
64 [K]SP D185 *BCU
[ 0 to 50 / 27
/ 1 µA/step ]
65 [FC,K]SP D62.5 *BCU
[ 0 to 50 / 9
/ 1 µA/step ]
66 [FC,Y]SP D62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
67 [FC,M]SP D62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
68 [FC,C]SP D62.5 *BCU
[ 0 to 50 / 7
/ 1 µA/step ]
69 [FC,K]SP D125 *BCU
[ 0 to 50 / 15
/ 1 µA/step ]
70 [FC,Y]SP D125 *BCU
[ 0 to 50 / 10
/ 1 µA/step ]
71 [FC,M]SP D125 *BCU
[ 0 to 50 / 10
/ 1 µA/step ]
301
72 [FC,C]SP D125 *BCU
[ 0 to 50 / 10
/ 1 µA/step ]
[Cur.Paper Size] Transfer Current - Paper Size Correction
Paper Type -> N: Normal, TH: Thick, OHP
Corrects the transfer current for paper size.
When small paper is used for printing, the transfer current flows to the drum at the non
image areas where the transfer belt touches the OPC drum. This may cause an abnormal
image due to insufficient current at the image areas.
NOTE: Increase only when an abnormal image (insufficient image transfer) occurs on a
small paper size. However, increasing the current too much may cause image
offset.
5 N LT SEF *BCU [ 1.0 to 4.0 / 1.4 / 0.1/step ]
6 N A5 SEF *BCU [ 1.0 to 4.0 / 1.8 / 0.1/step ]
7 TH LT SEF *BCU [ 1.0 to 4.0 / 1.2 / 0.1/step ]
309
8 TH A5 SEF *BCU [ 1.0 to 4.0 / 1.4