PRINTER ENGINE SERVICE MODE 17 January, 2003
5-72
7
Mode No.
(Class 1, 2, and 3)
Function / [ Setting ]
[Alert Display]
10 Wst Oil: Full *
BCU
Specifies the number of revolutions the
development drive motor-K can make after the
message, “Waste Oil Bottle is Almost Full”, is
displayed.
[ 232 to 464 / 232 / 1 kilo-revolutions/step ]
The machine stops after the motor has made the
specified number of revolutions.
This SP specifies the interval from near end to end
for the waste oil bottle. 232k revolutions equals
2.5k prints. If it is set to 464, the end condition is
5.0k prints after near end.
905
14 Oil: Alert: Page *
BCU
Specifies the number of sheets the machine can
output after the oil supply reaches the near-end
condition.
[ 25.0 to 27.5 / 27.5 / 0.1 kilo-sheets/step ]
[PMCounter-PREV] PM Counter - Previous
(Sheets or Rotations, Unit, [Color]), Dev.: Development Unit
1 S:PCU [K]
2 S:PCU [Y]
3 S:PCU [M]
4 S:PCU [C]
5 S:Dev. [K]
6 S:Dev. [Y]
7 S:Dev. [M]
8 S:Dev. [C]
9 S:Oil Supply
10 S:Fusing
Displays the number of sheets printed with the
previous maintenance units.
[ 0 to 9999999 / 0
/ 1 sheet/step ]
11 R:PCU [K]
12 R:PCU [Y]
13 R:PCU [M]
14 R:PCU [C]
15 R:Dev. [K]
16 R:Dev. [Y]
17 R:Dev. [M]
18 R:Dev. [C]
19 R:Oil Supply
20 R:Fusing
Displays the number of revolutions for motors or
clutches in the previous maintenance units.
[ 0 to 9999999 / 0
/ 1 revolution/step ]
21 S:Waste Toner
22 S:Toner [K]
23 S:Toner [Y]
24 S:Toner [M]
25 S:Toner [C]
Displays the number of sheets printed with the
previous maintenance unit or toner cartridge.
[ 0 to 9999999 / 0
/ 1 sheet/step ]
26 R(%): PCU [K]
27 R(%): PCU [Y]
28 R(%): PCU [M]
29 R(%): PCU [C]
30 R(%): Dev [K]
31 R(%): Dev [Y]
32 R(%): Dev [M]
33 R(%): Dev [C]
34 R(%): Oil Spply
906
35 R(%): Fusing
*BCU
Displays the value given by the following formula:
(Current count ÷ Yield count) x 100, where
“Current count” is the current values in the counter
for the part, and “Yield count” is the recommended
yield.
[ 0 to 999 / 0 / 1 %/step ]