Technical Bulletin PAGE: 2/6
Reissued:01-Dec-11
Model:
Taurus-C1/P1 (D074/D075/M044) Date: 13-Sept-2011 No.: RD074022a
Current specification
Optimized registration adjustment value in the sub-scan
direction is input to SP1001 for each paper weight at the
factory, which is then input manually in SP1950 and 1951
to reflect the optimum registration for each custom paper
in use.
Front Side Back Side
Paper Weight 1 SP1001-001 SP1001-001
Paper Weight 2 SP1001-002 SP1001-002
Paper Weight 3 SP1001-003 SP1001-003
Paper Weight 4 SP1001-004 SP1001-004
Paper Weight 5 SP1001-005 SP1001-005
Paper Weight 6 SP1001-006 SP1001-006
Paper Weight 7 SP1001-007 SP1001-007
Custom Paper 1 SP1950-001 SP1951-001
Custom Paper 2 SP1950-002 SP1951-002
…
Custom Paper 100 SP1950-100 SP1951-100
For example, if “Custom Paper 1” corresponds to Paper Weight 3 (80.1 – 105.0gsm),
the value of SP1001-003
is manually input to SP1950-001 and 1951-001.
The same adjustment can also be done in the Advanced Settings instead of the SP by
applying the value to Custom Paper; “08: Adj. Image Position of Side 1 With Feed (=
SP1950)” and “09: Adj. Image Position of Side 2 With Feed (= SP1951)