Technical Bulletin  PAGE: 1/1 
Reissued:28-Mar-14 
Model: Taurus-C1a/C1b (D074/D075) 
 
RTB Reissue 
The items with a line drawn through them have been deleted. 
 
IMPORTANT NOTICE 
With Engine f/w version 1.66:04 1.67.04 or newer, the fusing ID chip can store the PM 
counter of the web cleaning unit. 
 
 
How to enable the new feature: 
Set SP1-998-001 to ‘1’ (enable). The PM counter stored on the fusing ID chip will 
synchronize with the counter stored in the engine. 
 
 
For machines that use multiple fusing units: 
DO NOT swap the web cleaning unit.  Always use the same web cleaning unit and fusing 
unit as a set. 
 
 
Web cleaning unit replacement procedure: 
Do either of the following after replacing the web cleaning unit (to synchronize the PM 
counter): 
  Clear the web cleaning unit PM counter 
  Print 50 pages 
 
 
Synchronization of the web cleaning unit PM counter is performed as follows: 
 
  Clear PM counter      : Engine    Fusing ID chip 
 
  Print 50 pages    : Engine    Fusing ID chip 
 
  Replace the fusing unit and 
web cleaning unit as a set  : Fusing ID chip    Engine 
 
 
Note: See RTB RD074110 for procedures on how to replace PM parts of the fusing unit 
for machines that use multiple fusing units. 
 
Subject: <Spec change> Storage of web cleaning unit PM 
counter on the fusing ID chip 
Prepared by: Akihiro Tajima 
From: 1st PP Tech Service Sec., PP Tech Service Dept., 
 Mechanical 
 Paper path 
 Product Safety  
 Electrical 
 Transmit/receive 
 Other (          ) 
 Service manual revision 
 Retrofit information 
 Tier 2