Technical Bulletin PAGE: 1/1
Model: Taurus-C1/P1
Date: 28-APR-17
No.: RD074140
Service Manual Correction
Please add the following SC Codes to your FSM, in this section:
6. Troubleshooting: SC Tables SC500: Paper Feed, Transport, Duplexing
SC No.
Level
Error Name/Error Condition/Major Cause/Solution
SC563-00
A
Overheat detection (software): Heating Roller NC Sensor
Heating Roller NC Sensor detected 255 degrees or higher 10
seconds consecutively.
Measurement period: 100 milliseconds
Triac shorted.
IOB board defective.
Fuser Unit controller software runaway
Replace the IOB board.
Replace the Fuser Unit.
Subject: Service Manual Correction: SC table added