Technical Bulletin  PAGE: 1/1 
Model: Taurus-C1/P1 (D074/D075/M044) 
 
Subject: FSM Correction: SC467 description added 
From: 1st Tech Service Sect., PP Tech Service Dept. 
 Mechanical 
 Paper path 
 Product Safety  
 Electrical 
 Transmit/receive 
 Other (          ) 
 Service manual revision 
 Retrofit information 
 Tier 2 
Please add the following description on SC467 to your field service manual in section: 
 
Appendices  6. Troubleshooting  SC Tables  SC400: Around the Drum 
 
 
 
SC467 PTR AC Transfer power pack leak error 
 
An interrupt checks the status of the power pack every 10 ms.  
This SC is issued if a problem exists with 50 consecutive samplings (500 ms). 
 
Check if the drawer unit is closed correctly using the following procedure. 
 
1.  Turn off the machine power and pull out the drawer unit. 
2.  Close the drawer unit completely and turn on the machine power. 
3.  Make two or three copies and confirm the error message has disappeared. 
 
Remove the high voltage cable from the output terminal of the AC Transfer power pack 
and check the following items. 
 
  PWM signal check 
If signal is fixed during image transfer, replace the cable or the IOB. 
 
  AC Transfer power pack output check 
If output is fixed during image transfer, replace the power pack. 
 
If output is normal during image transfer, replace the high voltage cable or the 
quenching needle.