Technical Bulletin  PAGE: 1/3 
Model: Taurus-C1a/C1b (D074/D075) 
 
Subject: Troubleshooting SC449  
Prepared by: Shinnosuke Sasaki 
From: 1st PP Tech Service Sec., PP Tech Service Dept., 
 Electrical 
 Transmit/receive 
 Service manual revision 
 Retrofit information 
 
Symptom 
SC449 (ITB Tray Lift [K] error) occurs and the Bk image transfer roller remains up against 
the drum even when releasing the ITB lock lever or turning the screw to lower the right half 
of the ITB unit according to the procedure in the following section of the field service 
manual. 
 
4. Replacement and Adjustments > Common Procedures > Pulling Out the ITB Unit > 
Before Pulling Out the ITB Unit and PCDUs 
 
Check if the Bk image transfer roller is raised up against the drum by looking at the front 
edge of the ITB.  If you see the white cap as shown in the photo below, the ITB lift motor 
has failed to lower the belt. 
 
 
 
 
Cause 
Following are the possible causes of this problem. 
1.  The 2nd lift motor or its gear is clogged with toner. 
2.  The 2nd lift motor sensors are dirty or damaged. 
3.  Damaged or disconnected harnesses