SYMPTOM
Banding (uneven density) at 50mm intervals
CAUSE
Gap between the drum and
development roller
fluctuates.
Drive gear and coupling
gear of the development
roller are misaligned.
Align the drive gear and
coupling gear. (Step 1)
Development unit is of the
old type (D0742301-03).
Replace with the latest
development unit. (Step 4)
Development unit was
damaged during transport.
Toner/developer
degradation
Refresh toner. (Steps 2&3)
Replace developer. (Step 4)
Recommended Action
Step1:
Are the markings on the drive gear and coupling gear of the development roller
aligned?
Yes : Go to step 2.
No : Do the “Development roller Drive gear – Coupling gear alignment
procedure” described in the last part of this bulletin.
Print the image showing the problem. Has the problem been resolved?
Yes : Finished.
No : Go to step 2.