Technical Bulletin PAGE: 1/1
Model: Taurus-C1/P1 Date: 13-Feb-12 No.: RD074043
Subject: Service Manual Correction (SC599) Prepared by: Shinnosuke Sasaki
From: 1st PP Tech Service Sec., PP Tech Service Dept.,
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety Other (Manual
Correction)
Tier 2
Please apply the following corrections to your Taurus field service manual in the section:
6. Troubleshooting > SC Tables > SC500: Paper Feed, Transport, Duplexing
Correction
Correct:
SC599 Cooling Box Sensor Error
The cooling box sensor detects unusual values.
z The cooling liquid dropped below the threshold
z Connector disconnected or defective
z IOB defective
z Harness shorted
Incorrect: The following description in the current FSM is incorrect
Note
The possible actions for this SC are as follows:
z Fix the leak and refill the liquid.
z Reconnect the connectors.
z Replace the sensor.
z Replace the IOB board.
z Replace the harness.