Technical Bulletin  PAGE: 1/2 
Taurus-C1/P1 
 7-May-18 
RD074141 
Part for Charge Roller Lever Replacement
H Kawamura
From: PPCS Section, CIP Product Quality Management Dept.  
Classification: 
 Troubleshooting 
 Mechanical 
 Paper path 
 Part information 
 Electrical 
 Transmit/receive 
 Action required 
 Service manual revision 
 Retrofit information 
 Product Safety    Other (          )   Tier 2   Tier 0.5 
SYMPTOM 
The Charge Roller Lever becomes damaged, requiring the replacement of the entire 
PCDU assembly. 
CAUSE 
Inserting the PCDU into the machine without securing the Charge Roller Lever. 
SOLUTION 
Apply the Charge Roller lever on top of the broken part 
Part Number : D1949100 
Part Description : Charge Roller Lever 
Note: This solution only works if the remaining part in the red circle is still in the PCDU 
<Procedure for applying the part> 
1. Pull out the affected PCDU
2. Turn the broken lever to the close position