Technical Bulletin PAGE: 2/2
Model: Taurus-C1/P1 (D074/D075/M044) Date: 13-Feb-12 No.: RD074044
D
2. Clean the doctor gap of the affected color.
z Cut out an OHP transparency [A] or a plastic sheet as shown below.
z Clean the doctor gap using the sheet and then vacuum the remaining developer.
Note
This procedure is almost the same as the procedure for troubleshooting “Vertical white
line” as described in the service manual in the section:
6. Troubleshooting > Troubleshooting for Image Quality Problems > Development-
related Troubleshooting > Vertical White Line
The procedures are similar because a clog in the doctor gap could have opposing results
in which the developer supply is either insufficient or excessive.