Technical Bulletin PAGE: 8/9
Model: Taurus-C1/P1 (D074/D075/M044) Date: 15-Feb-12 No.: RD074045
The following are the differences in the Tera Term settings in comparison with the BCU.
Serial port setup
[Baud rate] is “115200”. (BCU is “57600”.)
[Transmit delay] is both set to “5”. (BCU is “10” and “0”.)
Terminal set up
[Transmit] is “CR”. ([Transmit] for BCU is “CR+LF”.)
Do NOT enable the check box for
[Local echo]. ([Local echo] is specified for the BCU.)
After making the above settings, capture the logs in the same manner as done for the BCU.