Technical Bulletin PAGE: 5/14
Model: Taurus-C1 (D074/D075) Date: 22-Jun-2011 No.: RD074015a
The following table is an excerpt from the reference table describing the SP codes and the
corresponding PM parts in the section "Preventive Maintenance > PM Tables for Main
Machines > ARDF > SP Setting Summary" of the service manual.
Procedures indicated “Yes” in red in the column “Installation” have been deleted.
Task Details Installation
1 PM Parts Applicable part only
2 Set Toner Bottle Yes
3 Open Front Doors Both left, right doors Yes
4 Main Power ON Yes
5 Enter SP Mode Yes
6 Reset PM Part Applicable part only
7 Install Developer SP3024-001(K)
SP3024-002 (C)
SP3024-003 (M)
SP3024-004 (Y)
Yes
8 Developer File OK? SP3025-001
Results for YMCK
reading left to right
Yes
9 Apply Lubricant 1. Open right front door.
2. SP2310-001
3. Close right door.
10 Close Front Door Yes
11 Wait for Warmup ("Ready") Wait 5 min. for the
audible beep and the
"Ready" message on
the operation panel.
Yes
12 Manual Toner Fill SP3051-001 Yes
13 Cleaning SP3032-001 (All)
SP3032-02 (CMY)
SP3032-03 (K)
SP3032-04 (C)
SP3032-05 (M)
SP3032-06 (Y)
Yes
14 Initialize TD Sensor SP3030-01 (All)
SP3030-02 (CMY)
SP3030-03 (K)
SP3030-04 (C)
SP3030-05 (M)
SP3030-06 (Y)
Yes
15 Confirm TD Sensor Initialization SP3031-001
Results for YMCK,
reading left to right.
Yes
16 Initialize Process Control SP3020-001 Yes
17 Confirm Process Control Initialization SP3012-001 Yes
18 Exit SP Mode Yes