Technical Bulletin PAGE: 7/9
Model: Taurus-C1/P1 (D074/D075/M044)
Date: 20-Jul-12
No.: RD074081
After the installation
5 Execute SP 3011-4 (Full MUSIC).
a. If MUSIC succeeds without any SC, do the following :
a-1. Clear the skew motor adjustment value by executing the following SPs. Clear
only the values of the stations that have a new skew motor.
SP2104-31 Clear Revision C
SP2104-32 Clear Revision M
SP2104-33 Clear Revision Y
a-2. Go to step 6.
b. If SC26x occurs after MUSIC, do the following:
b-1. Clear the skew motor adjustment value by executing the following SPs. Clear
only the values of the stations that have a new skew motor.
SP2104-31 Clear Revision C
SP2104-32 Clear Revision M
SP2104-33 Clear Revision Y
b-2. Execute MUSIC again.
b-3. If SC26x persists, repeat b-1 and b-2 until SC26x is cleared.
Note
b-1 and b-2 may have to be repeated several times to clear SC26x.
6 Make sure the value(s) of the following SP(s) are 0.
SP2104-7 Accumulation present value C
SP2104-8 Accumulation present value M
SP2104-9 Accumulation present value Y