Technical Bulletin PAGE: 2/2
Reissued:27-Sep-13
Model:
Taurus-C1/P1 (D074/D075/M044) Date: 18-Oct.-2011 No.: RD074024a
Notes on the Anti-condensation Function (SP1-945-018)
1) Enabling the anti-condensation function activates the 2 exhaust fans on
the left side of the machine during warm-up and idling, if the temperature is
below 20 degrees Celsius. This increases the temperature of the guide
plate and prevents condensation.
2) This SP is available with the following firmware. For more details about
this SP, see the release notes.
Copier
Firmware Version (Copier) Program No.
Engine 1.58.04 or newer D0745404E or newer
System/Copy 1.07 or newer D0745773F or newer
Websys 1.06 or newer D0745777C or newer
Printer
Firmware Version Program No.
Engine 1.58.04 or newer M0445404C or newer
System/Copy 1.03 or newer M0445773C or newer
Websys 1.04 or newer M0445777B or newer
Expiration
This is to announce the expiration of the information originally delivered in this
bulletin. Considering the time elapsed since August 2011 when the modification
of the guide plate was implemented, it is expected that the guide plate of the
previous type (D0742195) is no longer used in the field and the requested
actions (crossed out below) have been completed.
Request
1.
On installing, please check whether the three guide plates of fusing unit are old or
countermeasured ones.
Old parts have no
ribs on the guide plate.
Countermeasured parts have some
ribs on the guide plate.
Refer to the procedure which showed the
old ones and the countermeasured ones
2.
If the guide plates are old ones, contact our service key person in RAC, replace the three
guide plates with countermeasured ones
Procedure
[Deleted]