Technical Bulletin PAGE: 2/7
Reissued:14-Oct-14
Model: Taurus-C1a/C1b (D074/D075)
What needs to be done
Do the new procedures A~B where indicated with the tick () which depend upon the
maintenances performed for the drum and drum cleaning unit (1~6 and their
combinations).
Lubrication of
the cleaning
brush
Lubrication of
the cleaning
blade edges
Manually
rotating the
drum
Initializing the
cleaning unit
Drum/Cleaning unit:
Replaced.
Drum/Cleaning unit:
Cleaned
Drum/Cleaning unit: Reset
IMPORTANT
If maintenance has to be performed for the PCDU and ITB unit/ITB cleaning unit, make
sure to completely finish the maintenance of either of the units before working on the other
unit, to prevent the system from running the initialization process without sufficient
lubrication.
See the following pages for details on each procedure.