Technical Bulletin PAGE: 2/3
Model: Taurus-C1a/C1b (D074/D075)
Date: 12-Jun-14
No.: RD074122
Solution
1. Check if the connectors of the potential sensor relay board are disconnected, loose, or
dirty.
If disconnected or loose, reconnect the connectors.
If dirty, clean the connectors.
If the above does not solve the problem, go to Step 2.
2. Check if the probe is dirty.
If dirty, clean the probe with air spray.
If the above does not solve the problem, go to Step 3.
3. Replace the potential sensor.