Technical Bulletin PAGE: 12/34
Reissued: 4-Jun-15
Model: Taurus-C1a/C1b/P1 (D074/D075)
Date: 17-Jun-14
No.: RD074119a
Prepare A3 or DLT size paper.
3.3.2 Adjustment procedure: Scanner calibration
NICE ver.2.0 has been added with a new scanner calibration function for higher FR
density adjustment precision.
1. Place a blank piece of A3/DLT paper on the contact glass. (See 2.3 ‘Common
procedure for scanning test charts’ for the correct scanning procedure.)
2. Insert the NICE SD card into the service slot on the controller box and press
Scan: Calibration for FR on the main NICE menu screen.
3. Remove the blank piece of paper from the contact glass.
IMPORTANT
The blank paper must be of the same paper used for printing test charts.
NOTE
Calibration data will be stored in the SD card.
Scanner calibration is required only once for multiple FR density adjustments
performed on the same day on the same machine.
Following paper types are not recommended: Colored paper, textured paper,
cast coated paper (Adjustment precision may decrease.)