Technical Bulletin PAGE: 29/34
Reissued: 4-Jun-15
Model: Taurus-C1a/C1b/P1 (D074/D075)
Pro C901: Productivity: Generic paper
Purple cells indicate the combinations that are not supported by spec.
If the SP value is ‘0’ (default), input 100% for productivity.
If the SP value is not ‘0,’ run a job under the following 2 conditions and time the
intervals with a stopwatch respectively:
Current SP value
Default SP value (0)
Then, divide the time generated with the current SP value by the time generated with
the default value to find out the productivity.
Pro C901: Productivity: Custom paper
SP1-207-001 ~ 100 (Default: 0)
If the SP value is ‘0,’ input 100% for productivity.
If the SP value is not ‘0,’ run a job under the following 2 conditions and time the
intervals with a stopwatch respectively:
Current SP value
Default SP value (0)
Then, divide the time generated with the current SP value by the time generated
with the default value to find out the productivity.