Technical Bulletin PAGE: 2/3
Reissued: 01-Dec-14
Modified Points or Symptom Corrected
2) RC1147, RC1148: Added a comment to Remarks
3) RC1169: Corrected weight setting
RC1142 unify the "Media Type"
1) RC0036, 0107, 0108, 0110, 0111, 0113, 0114, 0116, 0117, 0123, 0124:
Image Quality rank change to B
2) RC0112, 0122: Notes comment move to the Remark.
3) Wt.7 2nd side correction coefficient value deleted because duplex not
accept.
4) Add 10 media.
(NOTE*) Version 3.0 was omitted due to unavoidable
circumstances.
About the Media List
Media has been evaluated under 4 categories of “Image Quality”, “Image Permanence”, “Feed
Performance” and “Others”, which are ranked in 3 levels except for “Image Quality” evaluated in 4
levels. The lowest rank marked among the 4 evaluation categories is applied to the overall
evaluation rank for each media.
About the MQP file
The MQP file only contains data for media ranked ‘A’ in overall evaluation. Installing the MQP file
into the Taurus-C1a/C1b will enable application of the media from the Paper Library.
Better than the product Spec. (Only Image Quality)
Result is good without any remarks.
There is remark for use. Customer should know the remark for use.
Example of media evaluation results:
NOTE