Line regulation rate, ± (% of output + offset)
Current <0.01%+250 μA
Output Ripple and Noise
Output ripple and noise (20 Hz to 20 MHz)
Normal mode voltage <350 μV
rms
/2 mV
pp
Normal mode current <2 mA
rms
Accuracy 12 months (25ºC±5ºC)
Accuracy 12 months (25ºC±5ºC)
[2]
, ± (% of output + offset)
Programming Readback
Voltage Current Voltage Current
Low range
current
[3]
CH1 0.03%+8 mV 0.15%+5 mA 0.05%+8 mV 0.15%+5 mA 0.25%+28 μA
CH2 0.03%+8 mV 0.15%+5 mA 0.05%+8 mV 0.15%+5 mA 0.25%+28 μA
CH3 0.04%+4 mV 0.15%+10 mA 0.08%+3 mV 0.15%+10 mA Not available
Resolution
Resolution
Programming Readback Display
Voltage Current Voltage
Curre
nt
Low
range
current
[3]
Voltage
Curren
t
Low
range
current
[3]
CH1 1 mV 0.1 mA 0.1 mV
0.1
mA
1 μA 1 mV 0.1 mA 1 μA
CH2 1 mV 0.1 mA 0.1 mV 0.1
mA
1 μA 1 mV 0.1 mA 1 μA
CH3 1 mV 1 mA 0.1 mV 0.1
mA
Not
available
1 mV 0.1 mA Not
available
Transient Response Time
Transient response time
Less than 50 μs of time to recover to within the ±15 mV settling band following a
load change from 50% to 100% or from 100% to 50% of full load.
Specifications
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.
DP2000 User Guide
93

Table of Contents

Other manuals for Rigol DP2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rigol DP2000 Series and is the answer not in the manual?

Rigol DP2000 Series Specifications

General IconGeneral
BrandRigol
ModelDP2000 Series
CategoryPower Supply
LanguageEnglish

Related product manuals