Command Processing Time
Command processing time
[4]
<10 ms
OVP/OCP Accuracy
OVP/OCP accuracy, ± (% of output + offset)
OVP accuracy, ± (% of output +
offset)
0.2%+20 mV
OCP accuracy, ± (% of output +
offset)
0.5%+20 mA
Voltage Programming Response Time (Within 99% of the Total Variation Range)
Voltage programming response time (within 99% of the total variation range)
Channel Full Load (Up) No Load (Up) Full Load (Down) No Load (Down)
CH1 <50 ms <30 ms <50 ms <400 ms
CH2 <50 ms <30 ms <50 ms <400 ms
CH3 <15 ms <14 ms <20 ms <100 ms
Temperature Coefficient Per ºC
Temperature coefficient per ºC, ± (% of output + offset)
Channel Voltage Current
CH1 0.01%+4 mV 0.01%+2 mA
CH2 0.01%+4 mV 0.01%+2 mA
CH3 0.01%+4 mV 0.01%+3 mA
Mechanical Characteristics
Mechanical characteristics
Dimension 239 mm (W) x 157 mm (H) x 419 mm (D)
Weight 9.95 kg
Rack mount kit Three rack-units (3U), 1/2-rack form factor