R&S
®
ZVA/ZVB/ZVT   Trace Menu 
1145.1084.12 4.117  E-6 
• Pressing  Horizontal Line for a first time shows the line for the active trace and opens the 
numeric entry bar to define its position (response value). The (rounded) position is displayed 
near the left edge of the screen.   
• Pressing Horizontal Line for a second time hides the horizontal line for the active trace. 
Use the analyzer's drag-and-drop functionality to move the horizontal line symbol to the desired 
position. 
Remote control:
CALCulate<Ch/Tr>:DLINe:STATe ON | OFF
CALCulate<Ch/Tr>:DLINe