SAMSUNG Programming
DCS-816 February, 1999
MMC 605 (Page 1 of 1)
MMC: 605
ASSIGN EXTERNAL PAGE ZONE
DESCRIPTION:
Determines which relays will close when external page zone is accessed.
DCS-816 has one external page zone(5).
NOTE
One external page port and one common relay are located on the the base board. The
page relay has default DNs of 361. Optional port is 362(MMC 219)
PROGRAM KEYS
UP & DOWN Used to scroll through options
KEYPAD Used to enter selections
SOFT KEYS Move cursor left and right
SPK Used to store data and advance to next MMC
HOLD Used to clear previous entry
ACTION DISPLAY
1. Press TRSF 605
Display shows first page zone
EXT. PAGE ZONE:(5)
MEMBER 1:361
2. Dial page zone number (e.g. 5)
OR
Use UP or DOWN to select desired page zone
numbers and press RIGHT soft key to move the
cursor
EXT. PAGE ZONE:(5)
MEMBER 1:NONE
3. Dial member number (e.g., 1)
OR
Use UP or DOWN to select member numbers
and press RIGHT soft key to move the cursor
OR
Press LEFT soft key to return to step 2
EXT. PAGE ZONE:(5)
MEMBER 1:
4. Dial relay number via dial keypad (e.g., 361)
and press RIGHT soft key to return to step 2
OR
Press LEFT soft key to return to step 3 above
EXT. PAGE ZONE:(5)
MEMBER 1:361
5. Press TRSF to store and exit
OR
Press SPK to store and advance to next MMC
DEFAULT DATA: None
RELATED ITEMS: MMC 723 System Key Programming