PLC-WU3800 Expand Serial Command Functional Specifications
18/74
8.4 Image Command
8.4.1 CF_BRIGHT Command
Command
"CF_BRIGHT_%1”[CR]
%1
"000~063” --------------- Directly select Brightness setting value
"UP” ----------------------- Current Brightness setting value + 1
"DN ----------------------- Current Brightness setting value – 1
Details
Set Brightness value of user control
The value set by this command will not be saved to projector. Therefore, when
turning into Standby mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]
8.4.2 CF_CONT Command
Command
“CF_CONT_1”[CR]
%1
“000~063” --------------- Directly select Contrast setting value
“UP” ----------------------- Current Contrast setting value + 1
“DN” ----------------------- Current Contrast setting value – 1
Details
Set Contrast value of user control
The value set by this command will not be saved to projector. Therefore, when
turning into Standby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
"Error Code”[CR]
8.4.3 CF_COLOR Command
Command
“CF_COLOR_%1”[CR]
%1
“000~063” ---------------- Directly select Color setting value
“UP” ------------------------ Current Color setting value + 1
“DN” ------------------------ Current Color setting value - 1
Details
Set Color value of user control
The value set by this command will not be saved to projector. Therefore, when
turning into Standby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]
8.4.4 CF_TINT Command
Command
“CF_TINT_%1”[CR]
%1
“000~063” --------------- Directly select Tint setting value
“UP” ----------------------- Current Tint setting value + 1
“DN” ----------------------- Current Tint setting value – 1
Details
Set Tint value of user control
The value set by this command will not be saved to projector. Therefore, when
turning into Standby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]