PLC-WU3800 Expand Serial Command Functional Specifications
55/74
9.7 Input Status Read Command
9.7.1 CR_INPUT Command
Command
“CR_INPUT”[CR]
Details Get selected INPUT No.
Response
Acceptable “000_%1”[CR]
Request data
“1”-”6”
Unacceptable
“Error code”[CR]
9.7.2 CR_SOURCE Command
Command
“CR_SOURCE”[CR]
Details Get selected Source
Response
Acceptable “000_%1”[CR]
Request data
“ANALOG” ---------- Analog (RGB) Input is selected
“SCART” ------------- SCART is selected
“HDMI” ---------------- HDMI is selected
“VIDEO” -------------- Video Input is selected
“S-VIDEO” ----------- S-Video Input is selected
“YPBPR” ------------- Component Input is selected
“NETWORK” -------- Network is selected
Unacceptable
“Error code”[CR]
9.7.3 CR_SRCINP1 Command
Command
"CR_SRCINP1” [CR]
Details Get selected source of Input 1_CMP1
Response
Acceptable “000_%1”[CR]
Request data
“ANALOG” --------- Analog Input is selected
“YPBPR” ----------- YPBPR Input is selected
“SCART” ----------- Scart Input is selected
Unacceptable
“Error code”[CR]
9.7.4 CR_SRCINP2 Command
Command
"CR_SRCINP2” [CR]
Details Get selected source of Input 2_CMP2
Response
Acceptable “000_%1”[CR]
Request data
“ANALOG” -------- Analog Input is selected
“OUT” ----------------Monitor out is selected
Unacceptable
“Error code”[CR]
9.7.5 CR_SRCINP3 Command
Command
"CR_SRCINP3” [CR]
Details Get selected source of Input 3_HDMI
Response
Acceptable “000_%1”[CR]
Request data
“HDMI” -------------- HDMI is selected
Unacceptable
“Error code”[CR]