PLC-WU3800 Expand Serial Command Functional Specifications
59/74
9.8 Screen Status Read Command
9.8.1 CR_SCREEN Command
Command
“CR_SCREEN”[CR]
Details Get selected on-screen image size
Response
Acceptable “000_%a”[CR]
%a
Input
is
PC
“NORMAL” --------------- Normal mode is selected
“TRUE” -------------------- True mode is selected
“FULL” --------------------- Full mode is selected
“CUSTOM” ---------------- Custom mode is selected
When the screen is set to D.Zoom, projector returns the previous
status (NORMAL )
Input
is
Video
“NORMAL” ---------------------- Normal mode is selected
“ZOOM” -------------------------- Zoom mode is selected
“NATURAL” --------------------- Natural wide is selected
“WIDE” ---------------------------Wide mode is selected
“FULL” --------------------------- Full mode is selected
“CUSTOM” ---------------------- Custom size is selected
Unacceptable
“Error Code”[CR] ------ When the command is invalid due to
condition such as Input source
“?”[CR] ----------------------- When unclear command is received
9.8.2 CR_ KYSTNMODE Command
Command
“CR_KYSTNMODE”[CR]
Details Get setting status of Keystone Store Mode
Response
Acceptable “000_%a”[CR]
%a
“STR” ---------------------- Store mode is “Store”
“RST” ---------------------- Store mode is “Reset”
Unacceptable
“Error code”[CR]
9.8.3 CR_VSCALE Command
Command
“CR_VSCALE”[CR]
Details Get setting status of Vertical Scale Store Mode
Response
Acceptable “000_%1[CR]
%1 “-32” ~ “032”
Unacceptable
“Error code”[CR]
9.8.4 CR_VPOS Command
Command
“CR_VPOS”[CR]
Details Get setting status of Vertical Position Store Mode
Response
Acceptable “000_%1”[CR]
%1 “-15” ~ “015”
Unacceptable
“Error code”[CR]