PLC-WU3800 Expand Serial Command Functional Specifications
47/74
8.11.4 CF_FREEZE Command
Command
“CF_FREEZE_%1”[CR]
%1
“ON” ------------------------ Set Freeze to ON
“OFF” ----------------------- Set Freeze to OFF
“UP” ------------------------------ Switch setting (On Off On ・・・)
“DN” ------------------------------ Switch setting (On Off On ・・・)
Note) “UP” and “DN” behave the same.
Details
Set/Cancel Freeze setting.
Although projector returns “000”, receiving another Freeze command does not
release Freeze operation.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]
8.11.5 CF_VMUTE Command
Command
“CF_VMUTE_%1”[CR]
%1
“ON” --------------------------- Set No show ON
“OFF” ------------------------- Set No show OFF
“UP” ------------------------------ Switch setting (On Off On ・・・)
“DN” ------------------------------ Switch setting (On Off On ・・・)
Note) “UP” and “DN” behave the same.
Details
Set/Cancel No show setting.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]
8.11.6 CF_PTIMER Command
Command
“CF_PTIMER_%1”[CR]
%1 “SET” ---------------Execute P-TIMER
Details
Display / Suspend / Cancel P-TIMER
This command behaves the same as “P-TIMER” key of Remote Control /
Projector.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]