PLC-WU3800 Expand Serial Command Functional Specifications
19/74
8.4.5 CF_SHARP Command
Command
“CF_SHARP_%1”[CR]
%1
“000~015” ---------------- Directly select Sharpness setting value
“UP” ------------------------ Current Sharpness setting value + 1
“DN” ------------------------ Current Sharpness setting value - 1
Details
Set Sharpness value of user control
The value set by this command will not be saved to projector. Therefore, when
turning into Standby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code”[CR]
8.4.6 CF_GAMMA Command
Command
“CF_GAMMA_%1”[CR]
%1
“000~015” ---------------- Directly set Gamma setting value
“UP” ------------------------ Current Gamma setting value + 1
“DN” ------------------------ Current Gamma setting value – 1
Details
Set Gamma value of user control
The value set by this command will not be saved to projector. Therefore, when
turning into Standby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code”[CR]
8.4.7 CF_WBAL - Command
Command
“CF_WBAL-%1_%2”[CR]
%1
“R” --------------------- Red
“G” --------------------- Green
“B” --------------------- Blue
%2
“000~063” ----------- Directly select Color value specified by White Balance%1
“UP” ------------------- Current Color value set by White Balance%1 + 1
“DN” ------------------- Current Color value set by White Balance%1 - 1
Details
Set Color value set by White Balance%1 of user control
The value set by this command will not be saved to projector. Therefore, when
turning into Standby-mode or ALL is OFF, the value returns to original setting. (The
value is held in Suspend mode.)
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code”[CR]