EasyManua.ls Logo

Sanyo PLC-WU3800 - Computer Input; Image Adjustment Options

Sanyo PLC-WU3800
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PLC-WU3800 Expand Serial Command Functional Specifications
36/74
8.10 Setting Command
8.10.1 CF_LANG Command
Command
“CF_LANG_%1”[CR]
%1
“ENG” --------------------------- Select English
“DEU” --------------------------- Select German
“FRA” --------------------------- Select French
“ITA” ----------------------------- Select Italian
“ESP” ---------------------------- Select Spanish
“POR” --------------------------- Select Portuguese
“NED” --------------------------- Select Dutch
“SVE” --------------------------- Select Swedish
“RUS” --------------------------- Select Russian
“CHI” ---------------------------- Select Chinese
“KOR” --------------------------- Select Korean
“JPN” --------------------------- Select Japanese
“FIN” ---------------------------- Select Finnish
“POL” --------------------------- Select Polish
“HUN” -------------------------- Select Hungarian
“ROM -------------------------- Select Romanian
“THA” -------------------------- Select Thai
Details
Set language for OSD
The language set by this command is stored in EEPROM and its setting is
effective after ALL is OFF.
This command is available in normal Power ON status.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]
8.10.2 CF_MENUPOSITION Command
Command
“CF_MENUPOSITION_%1”[CR]
%1 “SET” ------------------ Move the menu display to next position
Details
Change the menu position
This command is available in normal Power ON status.
The language set by this command is stored in EEPROM and its setting is effective
after ALL is OFF.
Position: top lefttop right – center – bottom left – bottom right – top left – …
Menu display appears with the first command when menu display is not shown on
the screen.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]
8.10.3 CF_AUTOSETUPPCADJ Command
Command
“CF_AUTOSETUPPCADJ_%1”[CR]
%1
“ON” ------------------- Set Auto PC ADJ. function to ON
“OFF” ------------------ Set Auto PC ADJ. function to OFF
Details
Set/Cancel Auto PC adj. function
This command is available in normal Power ON status.
Note) It is unable to set Keystone, PC ADJ. and Input search to OFF at once.
e.g. If projector receives Auto PC ADJ. OFF command while Keystone and Input
search are OFF, it returns error code “101”.
Response
Acceptable “000”[CR]
Unacceptable
“Error Code[CR]