30 VERSA SATEL
seconds can be programmed. Programming the value 0 means that the LED will be lit as
long as the partition is armed.
AC loss report delay – time during which the control panel must be without AC power
before the trouble is reported. A delay in reporting the trouble prevents sending information
about short-time voltage decays, having no effect on normal operation of the system. The
trouble reporting delay can be up to 255 minutes.
Tel. line loss report delay – time during which abnormal voltage must be on the telephone
line for the control panel to report the telephone line trouble. A delay in reporting the
trouble prevents sending information about short-time voltage dips (e.g. during a phone
call) or decays. The trouble reporting delay can be up to 255 minutes.
RTC clock correction – if the accuracy of control panel clock is inadequate, the clock
settings may be adjusted once per 24 hours (at midnight) by a defined time. The maximum
correction can be ±19 seconds per 24 hours.
Summer/winter time – the control panel can automatically adjust the clock settings due to
a change from the summer time to the winter time and vice versa. The following correction
schemes are available:
– no correction,
according to the European Union rules,
according to the United States' rules,
correction by 1 hour according to dates,
correction by 2 hours according to dates.
Summer time from / Winter time from – if the control panel clock is to be corrected by 1 or
2 hours according to dates, you should enter the dates (day, month) after the clock is
changed to the summer time (moved forward) or to the winter time (moved back).
4.4 Arming
Prevent arming if not ready – when the option is enabled, if the user arm the system by
means of keypad or keyfob, the control panel checks that there are no circumstances that
prevent the arming:
a zone with P
RIORITY option is violated in the partition which is to be armed,
– the 3. I
NSTANT, 4. DOUBLE KNOCK, 5. 24H BURGLARY, 6. 24H TAMPER, 7. 24H PANIC, 8. 24H
PANIC SILENT
, 9. 24H MEDICAL or 10. 24H FIRE type zone is violated in the partition which
is to be armed,
there is a trouble in the system.
If one of the aforementioned situations takes place, the control panel will not start the
arming procedure (the LCD keypad enables forced arming – see: U
SER MANUAL). If none of
the conditions is met, the control panel will start the arming procedure, but at the end of
the exit delay countdown it will check again if the arming is possible (the quick arming
being an exception). A violated zone or a trouble mean that the arming is not possible (i.e.
the arming procedure will fail).
Additionally, when the option is enabled and the user has the INSPECTION right, the LCD
keypad will inform, prior to arming, that there are bypassed zones in the partition (it does
not apply to the quick arming).
You can enable/disable the option in keypad: S
ERVICE MODE 2. HARDWARE 1. KPDS &
EXPS
. 4. OPTIONS ADVANCED ARMING.
Arm even if not ready after exit delay – if the option is enabled, a zone violation or trouble
found at the end of exit delay countdown does not affect the arming procedure – the
system will be armed. You can enable/disable the option in keypad: SERVICE MODE