78 VERSA SATEL
12. User schedules
The control panel offers 5 user schedules. The user schedule defines the user rights. When
adding or editing a user, one of the user schedules is selected.
The default settings of keyfob are tied to the user schedule. If a keyfob is assigned to the
user, the default keyfob settings will be suitable for the user schedule.
Changing the rights in user schedule results in a change of rights of all the users to
whom that schedule was assigned.
Changing the keyfob default settings has no effect on the settings of keyfobs which are
already added to the users.
12.1 Configuring the user schedules
You can configure the user schedules:
DLOADX program: “VERSA – Users” window “Users Schedules” tab (Fig. 26).
functions available in the USR TEMPLATES submenu (SERVICE MODE 8. USR TEMPLATES).
12.2 Parameters of the user schedule
Schedule name – individual name of the user schedule (up to 16 characters).
Right – defines which functions are available to the user. The following rights are available:
Arming – the user can arm the system.
Disarming – the user can disarm the system.
Alarm clearing – the user can clear alarms.
Tel. mess. clearing – the user can cancel messaging by means of the ABORT V.MSG. user
function (if he has at same time the ALARM CLEARING right and the CLEAR MESSAGING ON
ALARM CLEARING
global option is enabled, the messaging will be automatically canceled
when the alarm is cleared).
Auto-arming defer – using the A-
ARM DEFER. function ([CODE] 6. SETTINGS
1. A-
ARM DEFER.), the user can defer arming by the timer.
Zone inhibition – the user can inhibit the system zones by means of the INHIBIT function
([CODE] 4. BYPASSES 1. INHIBIT).
Zone isolation – using the I
SOLATE function ([CODE] 4. BYPASSES 1. ISOLATE),
the user having additionally the ZONE INHIBITION right can isolate the system zones.
Change access code – the user can change own access code (C
HANGE CODE function).
Users editing – the user can add, edit and delete users (USERS function).
Control – the user can control the outputs by means of the CONTROL function.
Programming – the user has access to the SETTINGS function, which allows him to
program the control panel clock, timers, telephone numbers for messaging and codes to
clear messaging.
DOWNLOAD/SERVICE – the user can define the rules of service access, initiate remote
programming of the control panel from the keypad and replace batteries in the wireless
keypads.
Inspection – the user has access to the EVENT LOG and SYSTEM STATE functions. In case
of arming by means of the LCD keypad, the user gets information about bypassed
zones and causes of denial of arming, if any (the user can enforce the arming).
Tests – the user has access to the TESTS submenu.