EasyManua.ls Logo

Satel Versa - Test Transmissions; Sia-Ip; Monitoring Station 1; Monitoring Station 2

Satel Versa
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SATEL VERSA 71
SIA – id. conf. required – if the option is enabled, the control panel will wait for
acknowledgement by the monitoring station of receiving the identifier with which the data
were sent. The option applies to telephone reporting.
Longer waiting for initial handshake – if the option is enabled, the control panel will wait
longer for handshake from the monitoring station in case of sending events in the Ademco
Express, Contact ID or SIA format. Enable this option in the event of telephone reporting, if
the monitoring station sends a non-standard initial handshake.
Long kiss-off signal – if the option is enabled, the control panel will accept a long kiss-off
(acknowledgment) signal for receiving events in case of Ademco Express and Contact ID
formats. Enable this option in the event of telephone reporting, if the monitoring station
acknowledges receiving events in a non-standard way (the kiss-off signal is longer than
800 ms).
10.2.3 Test transmissions
The test transmission may be sent:
at a specified time. The test transmission code will be sent regularly at a defined time. The
number of days between transmissions and the time of sending transmission are
programmed. Programming the value 0 for days means that the transmission will be sent
everyday (in the same way, as in case programming the value 1).
in specified time intervals. You can program the time intervals in which test transmissions
are to be sent when the system is disarmed and when the system is armed (number of
days, hours and minutes). The test transmission code will be sent:
after a predefined period of time has elapsed since the last transmission, irrespective of
whether it was a test transmission, or the code of another event was sent (the NO SYNC.
TO LAST TRANSMISSION
option disabled),
at predefined time intervals (the NO SYNC. TO LAST TRANSMISSION option enabled).
10.3 SIA-IP
10.3.1 Monitoring station 1 / Monitoring station 2
IP format – if the event codes are to be sent via Ethernet, specify whether SATEL format or
SIA-IP format (SIA DC-09 standard) will be used.
Protocol – if the event codes are to be sent via Ethernet, specify whether TCP or UDP
protocol will be used.
Options – options related to SIA-IP format:
Send MAC address – if this option is enabled, the MAC address is sent with event code.
Send timestamp – if this option is enabled, the date and time are sent with event code
(the monitoring station can change the date and time in the control panel).
Encrypt data – if the option is enabled, the data being sent are encrypted, and the date
and time are sent with event code (the monitoring station can change the date and time
in the control panel).
SIA-IP key – the key to encrypt data to be sent using the SIA-IP format.
hex – if the option is enabled, you can enter up to 32 hexadecimal characters as the
SIA-IP
KEY
. If the option is disabled, you can enter up to 16 alphanumeric characters as the
SIA-IP KEY.
SIA-IP acct – a string of up to 16 hexadecimal characters, which is used to identify the
control panel for the purpose of reporting in SIA-IP format.
Supervision interval – in the case of reporting in the SIA-IP format, an additional
transmission can be sent at specified intervals to check communication with the monitoring

Table of Contents