5. 24H BURGLARY – dedicated zone for the detectors which should be armed at all times (e.g.
glass break detectors).
6. 24H TAMPER – dedicated, permanently armed zone for tamper circuits. Violation of the zone
is additionally signaled as a trouble.
7. 24H PANIC – permanently armed zone, intended for operating the panic buttons.
8. 24H PANIC SILENT – permanently armed zone, intended for operating the panic buttons.
Alarm from the zone is not signaled on keypads, proximity card arm/disarm devices and
outputs, but the event code is sent to the monitoring station.
9. 24H MEDICAL – permanently armed zone for calling medical assistance.
10. 24H FIRE – dedicated, permanently armed zone for operating fire detectors.
11. DETECTOR MASK – permanently armed zone for antimasking control. Violation of the zone
is interpreted by the control panel as a detector trouble.
12. NO ALARM ACTION – the zone may be used to control the output with function 13. ZONE
VIOLATION
, 15. CONTROLLED or 16. READY STATUS. An additional option enables the zone
to be used for supervision of the key box (KEYBOX CONTROL option).
13. ARM/DISARM the zone controls the arming status of the partition it belongs to. Violation of
the zone starts the arming procedure or disarms the partition (depending on the current
status of the partition).
14. ARMING – violation of the zone starts the procedure of arming the partition to which the
zone belongs.
15. DISARMING – violation of the zone disarms the partition to which the zone belongs.
16. EXIT DELAY TERMINATOR – violation of the zone ends the partition exit delay countdown.
17. SHUNT LOCK – the zone ends the partition exit delay countdown and – depending on the
BLOCKS VERIFICATION option – will disable verification or disarm the partition to which it
belongs. The way of controlling (the zone violation / zone restore) is determined by the
option RESTORE DISABLES VERIF. or RESTORE DISARMS.
18. ENTRY ROUTE ENABLING – violation of the zone activates delay for the 2. ENTRY/EXIT ROUTE
type zones in the partition to which the zone belongs. The zones will act as delayed ones for
the D
ELAY ACTIVATION TIME. After expiry of the time, unless the system is disarmed, the
zones will again act as the instant ones. If the DELAY ACTIVATION TIME for a zone will be
programmed as equal to 0, and at the same time the E
NTRY DELAY programmed for the
partition is equal to 0, violation of the zone will have no effect.
19. TROUBLE – violation of the zone is treated by the control panel as a trouble. Additionally,
an alarm event may be written into the control panel memory (see: E
VENT parameter).
6.5 Zone options
Alarm on exit delay end – when the option is enabled, if the zone is violated at the
moment of ending the exit delay countdown, it will trigger an alarm (if this option is
disabled, the zone will only trigger the alarm when the status changes from normal
to violation during the armed mode).
Priority – if the option is enabled, arming is impossible when the zone is violated.
Bypass disabled – if the option is enabled, the user cannot bypass the zone.
Active in night arm – if the option is enabled, the zone is armed when the night armed mode
is activated.
Active in day arm – if the option is enabled, the zone is armed when the day armed mode is
activated.