SATEL VERSA 55
automatically upon starting the controller and after each operation of adding/removing
devices supported by it.
Test mode – in the ABAX system the test mode can be started, in which:
LED indicators are enabled in the wireless devices (the LEDs are disabled during
normal operation) – information provided by means of the LEDs depends on the device,
signaling is blocked in the ASP-105 and ASP-205 sirens.
The test mode is started/ended during polling, which results in a delay, its duration
depending on the programmed response period. The test mode will be turned off
automatically after 30 minutes of:
starting the test mode from the DLOADX program (the 30-minute period is running from
the moment of exiting the controller settings),
exiting the service mode in the control panel.
According to requirements of the EN50131 standard, the level of radio signals sent by
wireless devices is reduced during the test mode operation.
For the AMD-103 detector, entering the test mode remotely is not possible.
8.4.2 Parameters and options of ABAX system wireless devices
The wireless keypads constitute a special category of wireless devices for which a
separate group of positions is reserved in the controller. For information on configuring
the wireless keypads, refer to the manuals delivered with respective keypads.
Filter – the number of consecutive response periods, during which communication with the
device failed to be established, for the loss of communication with the device to be
reported. Values from the 0 to 50 range can be entered. Entering the digit 0 will disable
control of the device presence in the system.
In the case of the AMD-103 magnetic contact and ASP-100 siren, the presence check
is performed in a different way than for the other ABAX system devices. If the value
programmed for the FILTER parameter differs from 0, the lack of presence will be
reported if no transmission from the AMD-103 magnetic contact / ASP-100 siren is
received within one hour.
Always active [Active mode] – the option is available for the most of wireless detectors. If
enabled, the detector is permanently switched over to the active mode (see “ABAX
wireless detectors
p. 62).
The AMD-103 detector and the wireless detectors assigned to 24-h zones are always
in the active mode, therefore the ALWAYS ACTIVE option does not have to be enabled
for them.
Configuration – some of the wireless devices provide additional parameters and options,
which can be configured by radio (shown in square brackets is information on the zone for
which additional parameters can be programmed, if the device takes up more than 1
zone):
AGD-100 – wireless glass-break detector. Sensitivity is to be programmed.
AMD-100 / AMD-101 – wireless magnetic contact. The active reed switch is to be
selected.
AMD-102 – wireless magnetic contact with input for roller shutter detector. The following is
to be programmed:
active reed switch [first zone],