56 VERSA SATEL
number of pulses after which alarm will be triggered by the roller shutter input
[second zone]
time during which the specified number of pulses must occur for the roller shutter
input to trigger alarm [second zone].
AOCD-250 – wireless outdoor dual technology curtain detector. The following is to be
programmed:
sensitivity of PIR sensor;
sensitivity of microwave sensor.
AOD-200 – wireless outdoor dual technology motion detector. The following is to be
programmed:
sensitivity of PIR sensor;
sensitivity of microwave sensor;
sensitivity of dusk sensor (detection threshold).
APMD-150 – wireless dual technology motion detector. The following is to be
programmed:
sensitivity of PIR sensor,
sensitivity of microwave sensor,
the way of operation in test mode.
APD-100 – wireless passive infrared detector. The following is to be programmed:
sensitivity,
option of immunity to pets up to 15 kg.
ARD-100 – wireless reorientation detector. Sensitivity is to be programmed.
ASD-150 – wireless smoke detector. The following is to be programmed:
option to signal alarm from other ASD-150 detectors;
option to send out alarm to other ASD-150 detectors.
AVD-100 – wireless vibration detector and magnetic contact. The following is to be
programmed:
active reed switch [first zone],
sensitivity of vibration detector (registering a single vibration meeting the sensitivity
criterion will cause alarm) [second zone],
the number of pulses which, if registered by vibration detector will cause alarm (the
pulses need not meet the sensitivity criterion) [second zone].
Working parameters of the vibration detector are independently analyzed. The
detector can trigger alarm after registering a single, strong vibration caused by
a powerful impact, and also on registering several slight vibrations caused by a series
of weak strikes.
ASP-100 – wireless outdoor siren. The following is to be programmed:
type of acoustic signaling;
maximum duration of signaling.
ASP-105 – wirelessly triggered outdoor siren. The following is to be programmed:
type of acoustic signaling,
maximum duration of acoustic signaling.