SATEL VERSA 73
5. For the monitoring station to which event codes are to be sent:
define the format in which event codes will be sent (REPORTING FORMAT parameter),
if you select Ademco Express, Contact ID or SIA format, configure the additional
options (SIA – SEND PART. NAME, SIA – SEND SOURCE NAME, SIA – CONFIRM EACH BLOCK,
SIA – ID. CONF. REQUIRED, LONGER WAITING FOR INITIAL HANDSHAKE, LONG KISS-OFF
SIGNAL
),
program the identifiers to be sent with the event codes,
for the SIA or TELIM format, if the identifier is to consist of 6 characters, program SIA
/
TELIM PREFIX.
6. Define the parameters of test transmissions.
7. If a transmission format other than CONTACT ID (FULL) or SIA (FULL) is selected, program
the codes for events which are to be reported.
10.5.1 Reporting via telephone line
1. Enable the REPORTING – TELEPHONE option (see: “Global options” p. 27).
2. Program the monitoring station parameters:
– phone number,
– the number of attempts to connect to the station after which, if there is no connection,
the control panel will suspend reporting,
– time for which reporting will be suspended after the programmed number of attempts to
establish connection with the station has been made.
3. Configure the global options for telephone communicator:
– determine how the telephone numbers should be dialed (TONE DIALING; in case of the
pulse dialing option – PULSE 1/1,5 (OFF 1/2)),
– determine whether the control panel, prior to dialing the number, should check the
telephone line for dialing signal (NO DIAL TONE TEST),
– determine the reaction to signals received after dialing the number (NO ANSWER TONE
TEST
).
10.5.2 Reporting via Ethernet network
1. Enable the REPORTING – ETHM option (see: “Global options” p. 27).
2. Program the monitoring station parameters:
– monitoring station address,
– TCP port,
– data encryption key (STATION KEY),
– control panel identifier for the purposes of monitoring via Ethernet (ETHM KEY).
3. Define whether the events are to be sent in SATEL format or SIA-IP format (IP FORMAT).
4. If the SIA-IP format is to be used, configure the additional options and parameters (SEND
MAC ADDRESS, SEND TIMESTAMP, ENCRYPT DATA, SIA-IP KEY, HEX, SIA-IP ACCT and
SUPERVISION INTERVAL).
5. Specify whether TCP or UDP protocol is to be used.
6. Configure the Ethernet module network settings.
11. Messaging
The control panel can send notifications about system events by phone or by means of
e-mail messages.