54 VERSA SATEL
between the controller and the wireless devices takes place, the more wireless devices
can work within each other's operating range (12 seconds – up to 150, 24 seconds – up to
300, 36 seconds – up to 450). Beyond the response period, information about tampers of
devices and violations of detectors operating in active mode are sent to the controller. The
response period has an effect on the level of energy consumption by the wireless devices.
The less often communication between the controller and the wireless devices takes
place, the lower energy consumption and the longer battery life are.
In the case of the AMD-103 detector and ASP-100 siren, no communication takes
place during polling.
Fig. 17. DLOADX program: configuring the ABAX wireless system controller and ABAX
wireless devices.
Higher sensitivity for jamming detection – if this option is enabled, the sensitivity of
detection of radio communication jamming is boosted.
User can replace VERSA-LCDM-WRL battery – if this option is enabled, all users can
replace battery in the VERSA-LCDM-WRL wireless keypads (for 3 minutes after the code
is entered and confirmed with the key, the status of tamper switch will not be
monitored on the keypad that was used to enter the code). If the option is disabled, the
battery can only be replaced by the users who have access to the REPLACE BAT. function in
the 0.SERVICE submenu (the function is supported by the ABAX controller, firmware
version 5.03).
Synchronize – this function starts the procedure of synchronization, i.e. checking for
presence of other ABAX wireless system controllers working within the controller operating
range. The controller will synchronize the response period so that the radio transmissions
of some controllers should not be mutually jammed. Synchronization is performed