SATEL VERSA 39
Power-up delay – if the option is enabled, the zone is bypassed for 120 seconds after
power supply is turned on (this will prevent triggering false alarms e.g. during start-up
of the control panel).
Warning in partial arming – if the option is enabled and the partition is set to day or night
arm mode, the zone will trigger a warning alarm. It can be signaled in the keypad, in the
proximity card arm/disarm device or at the 2. INTERNAL SIREN function output. It is not
reported to the monitoring station. If you do not disarm the system during the warning
alarm, the zone will trigger a burglary alarm (see: parameter WARNING TIME p. 32).
Warning alarm in the partial armed mode will work irrespective of the WARNING ALARM
global option, which refers to the delay of loud signaling and reporting if any mistakes
are made when entering into the protected facility.
Warning on internal sirens – if the option is enabled, warning alarm in the partial armed
mode is signaled on the output with the 2. INTERNAL SIREN function.
Signaling on internal sirens – option for the 19. TROUBLE zone type. If it is enabled, the
zone violation is indicated on the internal sirens.
Auto-reset 3 – if the option is enabled, the zone can trigger up to 3 alarms. As long as the
alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not
trigger any alarm.
Auto-reset 1 – if the option is enabled, the zone can trigger only 1 alarm. As long as the
alarm is not cleared or the partition is not armed/disarmed, violations of the zone will not
trigger any alarm.
If the AUTO-RESET 3 and AUTO-RESET 1 options are enabled at the same time, the
AUTO-RESET 3 option will have priority.
Clearing Autoreset – if the option is enabled, the alarm counters for zones for which the
AUTO-RESET 3 or AUTO-RESET 1 option is enabled will be automatically reset at midnight
(violations of these zones will be able to trigger alarms again).
Armed if one part. armed – the option refers to the zones which are assigned to both
partitions. If the option is enabled, the zone is armed when one of the partitions is armed. If
the option is disabled, the zone is armed when both partitions are armed. The option is
also available in the event of ubypassing zones during disarming (if the option is enabled,
the zone will only be unbypassed after disarming both partitions).
Blocks verification – an option for the 0. E
NTRY/EXIT, 1. ENTRY/EXIT FINAL and 17. SHUNT
LOCK
zone types. If it is enabled, the zone will block alarm verification in the partition:
– after the zone violation – the 0. E
NTRY/EXIT and 1. ENTRY/EXIT FINAL zone types, and
also the 17. S
HUNT LOCK zone type, when the RESTORE DISABLES VERIF. option is
disabled,
– after the zone restore – the 17. SHUNT LOCK zone type, when the RESTORE DISABLES
VERIF
. option is enabled.
In case of the 17. SHUNT LOCK zone type, the zone will disarm the system when the
BLOCKS VERIFICATION option is disabled.
Restore disarms – an option for the 17. SHUNT LOCK zone type. If the option is enabled,
the zone restore will disarm the partition to which the zone belongs, and the zone
violation will shorten the exit delay time. If the option is disabled, the zone violation
will disarm the partition, and zone restore will shorten the exit delay time. The option
is available, if the BLOCKS VERIFICATION option is disabled.
Restore disables verif. – an option for the 17. SHUNT LOCK zone type. If the option is
enabled, the zone restore will block verification in the partition to which the zone belongs,
and the zone violation will shorten the exit delay time. If the option is disabled, the zone