32 VERSA SATEL
Partition exit delay – the time counted from the moment of starting the partition arming
procedure which enables the protected area to be left without triggering an alarm.
Violation of the 0. ENTRY/EXIT, 1. ENTRY/EXIT FINAL, 2. ENTRY/EXIT ROUTE or 4. DOUBLE
KNOCK
type zones during the exit delay time will trigger no alarm. Up to 255 seconds
can be programmed.
The exit delay countdown can be terminated by means of the 1. ENTRY/EXIT FINAL or
16. EXIT DELAY TERMINATOR type zones.
Using the keypad, you can arm the system without the exit delay, if the hold down
the key which ends the arming sequence ( , or ) for approx. 3
seconds.
Fig. 7. DLOADX program: configuring partition parameters in the “VERSA – Structure”
window.
Infinite exit delay – if the option is enabled, the partition exit delay can only be ended by
means of the 1. ENTRY/EXIT FINAL, 16. EXIT DELAY TERMINATOR or 17. SHUNT LOCK type
zones. If the exit delay countdown is not completed, the armed mode will not be activated
(only the 3. I
NSTANT type zones will be armed).
Entry delay – the time counted from the moment of entry into the protected area which
enables the partition to be disarmed before triggering an alarm. This parameter
applies to the 0. E
NTRY/EXIT and 1. ENTRY/EXIT FINAL type zones. The delay
programmed for the partition is taken into account in case of the zones for which the
value 0 has been individually programmed. The delay is programmed in seconds. Up
to 255 seconds can be programmed. If the value 0 is programmed, the zone will act
as an instant one.
Warning time – the time of warning alarm signaling for the partial armed mode (see:
WARNING IN PARTIAL ARMING zone option). The time is programmed in seconds. Up to 255
seconds can be programmed. If the value 0 is programmed, the W
ARNING TIME will be 30
seconds. After expiry of the W
ARNING TIME, unless the partition is disarmed, the burglary
alarm will be triggered.
The WARNING TIME parameter does not apply to the time of signaling the warning alarm
which is generated when mistakes are made when entering into the protected object
(see: WARNING ALARM global option).